MCU Compact Dry Cabinets (1% RH) for Small-Volume Storage of Electronic Components
The MCU series is a compact dry cabinet designed for ultra low humidity storage (1% RH) of electronic components and moisture sensitive devices (MSD).
It is ideal for space-saving applications and small-volume storage, providing reliable long-term protection in a compact footprint.
Maintains ultra low humidity (1% RH) under moderate door opening conditions (every 1–2 hours) Compared to larger MC and DXU models, the MCU series is optimized for compact size and space-saving installation. This compact dry cabinet provides ultra low humidity (1% RH) for long-term storage of electronic components and moisture sensitive devices (MSD). Alternative to nitrogen cabinets with lower running costs.
Ideal for:
- Small-volume storage of electronic components
- PCB and MSD storage
- Small-scale electronics manufacturing
- Laboratory and R&D environments
1 door Layout
2 door layout
3 door layout
2 door layout
2 door layout
135 liters
500 mm
570 mm
630 mm
approx. 30 kg
4
Extra low (1%RH)
USF-3200
AC230V 50/60 Hz
20 W/h (MAX 155 W)
2 years from the date of shipment
ESD-safe design
- Locks
- RH meter
- Earthing terminal
During our test, various doors were opened for around 20 seconds, with a 30-minute break in between. The McDry was able to constantly reduce the humidity to parameters that were within safe conditions.
The high-performance zeolite drying unit requires neither nitrogen nor does it need to be replaced: It recycles automatically.
ERC-301B
Specifications
Static capacitive sensor
Measuring range 1-70% RH
Accuracy: +/- 3% RH
4 AA alkaline batteries; approx. 1 year service life
Recommended for ISO-9000
The battery enables continuous measurement during power failures or relocations.
Our cabinets are manufactured in Japan from high quality steel and lockable doors. They have an anti-corrosion coating, a fully adjustable shelving system, glass windows and an ESD-safe design.
310 liters
500 mm
670 mm
1200 mm
approx. 60 kg
8
Extra low (1%RH)
USF-4000
AC230V 50/60 Hz
25 W/h (MAX 240 W)
2 years from the date of shipment
ESD-safe design
- Locks
- RH meter
- Earthing terminal
During our test, various doors were opened for around 20 seconds, with a 30-minute break in between. The McDry was able to constantly reduce the humidity to parameters that were within safe conditions.
The high-performance zeolite drying unit requires neither nitrogen nor does it need to be replaced: It recycles automatically.
ERC-301B
Specifications
Static capacitive sensor
Measuring range 1-70% RH
Accuracy: +/- 3% RH
4 AA alkaline batteries; approx. 1 year service life
Recommended for ISO-9000
The battery enables continuous measurement during power failures or relocations.
Our cabinets are manufactured in Japan from high quality steel and lockable doors. They have an anti-corrosion coating, a fully adjustable shelving system, glass windows and an ESD-safe design.
400 liters
500 mm
670 mm
1530 mm
approx. 70 kg
8
Extra low (1%RH)
USF-4000
AC230V 50/60 Hz
25 W/h (MAX 240 W)
2 years from the date of shipment
ESD-safe design
- Locks
- RH meter
- Earthing terminal
During our test, various doors were opened for around 20 seconds, with a 30-minute break in between. The McDry was able to constantly reduce the humidity to parameters that were within safe conditions.
The high-performance zeolite drying unit requires neither nitrogen nor does it need to be replaced: It recycles automatically.
ERC-301B
Specifications
Static capacitive sensor
Measuring range 1-70% RH
Accuracy: +/- 3% RH
4 AA alkaline batteries; approx. 1 year service life
Recommended for ISO-9000
The battery enables continuous measurement during power failures or relocations.
Our cabinets are manufactured in Japan from high quality steel and lockable doors. They have an anti-corrosion coating, a fully adjustable shelving system, glass windows and an ESD-safe design.
300 liters
880 mm
500 mm
980 mm
approx. 58 kg
3
Extra low (1%RH)
USF-4000
AC230V 50/60 Hz
25 W/h (MAX 240 W)
2 years from the date of shipment
ESD-safe design
- Locks
- RH meter
- Earthing terminal
During our test, various doors were opened for around 20 seconds, with a 30-minute break in between. The McDry was able to constantly reduce the humidity to parameters that were within safe conditions.
The high-performance zeolite drying unit requires neither nitrogen nor does it need to be replaced: It recycles automatically.
ERC-301B
Specifications
Static capacitive sensor
Measuring range 1-70% RH
Accuracy: +/- 3% RH
4 AA alkaline batteries; approx. 1 year service life
Recommended for ISO-9000
The battery enables continuous measurement during power failures or relocations.
Our cabinets are manufactured in Japan from high quality steel and lockable doors. They have an anti-corrosion coating, a fully adjustable shelving system, glass windows and an ESD-safe design.
520 liters
880 mm
800 mm
980 mm
approx. 80 kg
3
Extra low (1%RH)
UF-5000F
AC230V 50/60 Hz
31 W/h (MAX 350 W)
2 years from the date of shipment
ESD-safe design
- Locks
- RH meter
- Earthing terminal
During our test, various doors were opened for around 20 seconds, with a 30-minute break in between. The McDry was able to constantly reduce the humidity to parameters that were within safe conditions.
The high-performance zeolite drying unit requires neither nitrogen nor does it need to be replaced: It recycles automatically.
ERC-301B
Specifications
Static capacitive sensor
Measuring range 1-70% RH
Accuracy: +/- 3% RH
4 AA alkaline batteries; approx. 1 year service life
Recommended for ISO-9000
The battery enables continuous measurement during power failures or relocations.
Our cabinets are manufactured in Japan from high quality steel and lockable doors. They have an anti-corrosion coating, a fully adjustable shelving system, glass windows and an ESD-safe design.
OPTIONS
Tower light
Visual and audible alarm when the humidity reaches the set value.
N2 socket
For nitrogen flushing
Hygrometer with alarm
Standard in DXU-1001A and DXU-1002A. Includes alarm function.
Flow meter
Measures and controls nitrogen flow.
Bobbin stand
A large number of reels can be stored efficiently.
Data logger
The humidity data is recorded at all times.
Sliding shelves
Full length extendable.
Shelves
Stainless steel shelves are also available.
Would you like more information about our dry cabinets?
Reply within 24h • Free quote • Technical support
Overview of our dry cabinet series:
Discover our high-performance dry cabinets for various applications:
• DXU dry cabinets for ultra-low humidity (down to 1% RH)
• MC dry cabinets for standard industrial applications
• MCU dry cabinets for compact and flexible use cases