RELIABLE DRY STORAGE

When Your Materials Matter,
Humidity Control Matters.

Moisture-sensitive electronic components require appropriate storage conditions. Controlled dry storage can help reduce moisture-related risks during storage. McDry dry cabinets are designed to meet these demanding requirements.

01

Low Humidity Levels

Depending on the model, particularly low relative humidity levels can be achieved. The most suitable cabinet configuration depends on the specific requirements of your materials.

02

Controlled Storage Conditions

The drying technology helps maintain a dry storage environment and reduces dependence on changing ambient conditions.

03

Humidity Monitoring

The integrated humidity meter allows users to monitor the relative humidity inside the cabinet. Additional monitoring options are available depending on the selected configuration.

04

Designed for Long-Term Use

In addition to drying performance, McDry also considers maintenance, calibration and servicing — important factors for everyday industrial operations.

What matters is not only how low the humidity inside a cabinet can become, but also how reliably the required storage conditions can be maintained during daily operation.
UNDERSTANDING STORAGE RISKS

What Is the True Cost of a Disruption?

The purchase price of a dry cabinet is only one part of the decision. If the required dry storage conditions are interrupted, additional inspections, operational effort and delays may result.

01 / DISRUPTION

Interruption of Drying

A technical malfunction or power outage may affect the cabinet's active drying operation.

02 / HUMIDITY

Potential Rise in Humidity

Depending on ambient conditions, door openings and the duration of the interruption, humidity levels inside the cabinet may increase.

03 / MATERIALS

Additional Material Inspection

Depending on the components and their storage requirements, an assessment of the material condition may be necessary.

04 / PRODUCTION

Potential Production Delays

Release inspections, replacement materials or rescheduling may affect production operations.

What Is at Stake?

Not only the dry cabinet itself, but also the value of the stored materials, component availability and the stability of your production planning.

Why McDry?

McDry combines dry storage with a service-friendly design. When selecting a dry cabinet, maintenance and fault management should therefore be considered alongside drying performance.

INTERACTIVE RISK ASSESSMENT

What Could Moisture Exposure Cost Your Business?

Explore our interactive tools to estimate potential material losses or assess your storage risk.

3D PRINTING & R&D MATERIALS

Estimate Your Material Losses

Calculate indicative annual material losses based on material cost, consumption and moisture-related problems.

Calculate Material Losses →
AEROSPACE & AVIONICS

Assess Your Storage Risk

Evaluate component criticality, replacement difficulty and storage requirements to better understand your potential operational exposure.

Assess Storage Risk →

These tools provide indicative estimates and preliminary assessments only. Actual losses and storage requirements depend on operating conditions.

THE HIDDEN COST OF MOISTURE

What If Moisture Is Costing You More Than a McDry Cabinet?

Imagine that moisture-related defects account for 10% of the value of your annual materials or production. How much could better humidity control potentially save your business?

Calculate Your Current Loss

Start by estimating the annual value of materials or products at risk and the proportion potentially lost due to moisture-related problems.

Example: €2,000,000 per year. Use a consistent cost basis, such as material or production cost.

Example: 10%. This is an illustrative assumption, not an industry-average defect rate.

Estimated Annual Moisture-Related Loss

€200,000

Based on your entered annual value and assumed moisture-related loss rate.

Now consider the next question: What if better humidity control could prevent part of this loss?

Explore Your Potential Savings

Adjust the percentage below to explore different scenarios for reducing moisture-related losses.

50%
0% 50% 100%

Try 25%, 50% or 75% to compare hypothetical outcomes. The selected percentage is not a measured or guaranteed McDry loss-reduction rate.

Illustrative Annual Savings Potential

€100,000

Based on the assumed reduction in your estimated moisture-related losses. This is a scenario, not a forecast.

Important: This calculator provides illustrative scenarios only. The figures entered are user-defined assumptions, not measured McDry performance or guaranteed financial savings. Actual losses and achievable reductions depend on materials, production processes, storage conditions, operating practices and other factors. The calculation does not include cabinet purchase price, operating costs or other investment costs.

The purchase price is only one part of the equation.

Before asking what McDry costs, ask what moisture is already costing your business.

MODEL EXAMPLE: DXU-1001A

Two Dry Units.
One Thoughtful Design.

The McDry DXU-1001A is equipped with two dry units. Both units are located in the lower section of the cabinet, with one positioned on the left and the other on the right.

✓ Two Separate Dry Units
A model-specific configuration featuring two dry units installed in the lower section of the cabinet.
✓ Targeted Maintenance and Repair
Following an appropriate fault diagnosis, affected components can be inspected individually and replaced if necessary.
✓ Designed for Demanding Storage Applications
In addition to drying performance, maintenance requirements and serviceability are important selection criteria.

The positions of the dry units are shown in a simplified diagram. The illustration does not show the internal construction or wiring. If one unit fails, maintaining the specified humidity level cannot automatically be guaranteed.

McDry DXU-1001A

Location of the Two Dry Units

McDry DXU-1001A dry cabinet equipped with two dry units

Two Dry Units in the Lower Section of the Cabinet

↑
Dry Unit 1
Left
↑
Dry Unit 2
Right

Schematic indication of component positions – not an illustration of the internal components.

A SMARTER PURCHASING DECISION

The Lowest Purchase Price
Is Not Always the Lowest Cost.

A dry cabinet is a long-term investment in storage quality. When comparing quotations, the initial purchase price is only one part of the decision. Maintenance requirements, service coordination and the potential cost of moisture-related problems also deserve consideration.

THE QUESTION FOR PURCHASING TEAMS

What Will Your Dry Cabinet Really Cost Over Time?

Two cabinets may look similar on a quotation. But what happens after installation? Consider calibration procedures, service requirements, operational interruptions and the value of the materials being stored.

A typical price comparison Initial Purchase Price

Four Factors Worth Comparing

Look beyond the quotation and consider the full ownership experience.

01

Purchase Price

Compare the initial investment, cabinet capacity, humidity specifications and included features.

02

Maintenance & Calibration

Consider the time, labour, coordination and possible external service costs involved throughout the cabinet's life.

03

Operational Risk

Evaluate the potential impact of moisture exposure, material losses and interruptions to your storage process.

04

Long-Term Value

Consider serviceability, support availability and how well the cabinet fits your long-term requirements.

Where McDry Adds Practical Value

Removable Humidity Meter

The humidity meter can be removed and handled separately for calibration, without transporting the entire cabinet.

Service-Friendly Design

Relevant components, including the dry unit, can be inspected and replaced individually when required.

Support from SSG in Europe

Seika Sangyo GmbH supports customers with technical enquiries, troubleshooting and spare-parts coordination.

Two-Year Product Warranty

Cabinets supplied by SSG generally include a two-year product warranty starting from the SSG shipment date, subject to applicable terms.

The purchase price is only one part of the equation.

Make a Decision You Can Defend — Technically and Financially.

Choose a storage solution based not only on what it costs today, but also on the operational value it can provide over time. Let us help you evaluate the right McDry solution for your requirements.

Explore McDry Solutions

Total ownership costs and potential benefits vary according to cabinet configuration, operating conditions, maintenance practices and application. No specific cost saving or reduction in material losses is guaranteed.

RELIABLE, LOW-MAINTENANCE OPERATION

Less Maintenance.
Fewer Worries.

McDry dry cabinets are designed for reliable, long-term industrial operation with minimal routine maintenance requirements. Their straightforward, service-friendly construction helps reduce the maintenance burden in everyday use and makes targeted servicing possible if ever required.

McDry DXU-501A dry cabinet designed for low-maintenance industrial operation
McDry DXU-501A – Product Example

01 · Minimal Routine Maintenance

McDry is designed for everyday industrial use without complicated routine maintenance procedures, helping to reduce the operational workload.

02 · Designed for Long-Term Reliability

The drying system is designed for dependable, continuous operation. Its straightforward construction supports stable day-to-day use with limited maintenance demands.

03 · Service-Friendly Construction

If technical attention is ever required, key components can be inspected following fault diagnosis and replaced individually when necessary.

04 · European Support from SSG

Seika Sangyo GmbH supports customers across Europe with troubleshooting, suitable spare parts and technical service enquiries.

Easy Humidity Meter Calibration

One of the main routine maintenance considerations is periodic calibration of the humidity meter, according to your quality requirements. The McDry humidity meter is removable, allowing calibration to be arranged separately without transporting the entire dry cabinet. This helps simplify maintenance planning and reduce unnecessary handling of the equipment.

SERVICE-FRIENDLY DESIGN

Simple Maintenance, Even When Service Is Needed

McDry is designed to keep routine maintenance requirements low. In the event of a technical malfunction, servicing can often focus on the affected component rather than replacing the entire cabinet. The following examples illustrate this service-friendly approach.

Replaceable McDry dry unit
DRYING TECHNOLOGY

Replaceable Dry Unit

The dry unit is a key component of the McDry drying system. Should a relevant technical malfunction occur, it can be inspected separately following fault diagnosis and replaced if necessary.

  • Targeted fault diagnosis
  • Individual replacement when required
  • No automatic need to replace the entire cabinet
McDry Double Timer Unit for DXU-1001A and DXU-1002A
DXU-1001A & DXU-1002A ONLY

Double Timer Unit

The DXU-1001A and DXU-1002A models are equipped with a Double Timer Unit. If a relevant malfunction occurs, this component can be inspected and replaced separately when necessary.

  • Model-specific timer component
  • Individual inspection when required
  • Spare parts available through SSG
Important: Double Timer Unit Used in Two Models Only

The Double Timer Unit is installed exclusively in the DXU-1001A and DXU-1002A models. Other McDry models do not use this Double Timer Unit. Service requirements and spare parts depend on the cabinet model and the cause of any malfunction.

LONG-TERM COST EFFICIENCY

Compare More Than the Price.
Consider the Storage Risks.

A low purchase price alone says little about the long-term value of a dry cabinet. What matters is how well the system meets the requirements of your materials and production processes.

Selection Criteria What Should You Consider? The McDry Approach
Drying Performance What relative humidity level is required for the stored materials? Model-specific solutions for demanding dry storage applications.
Operational Reliability What would be the consequences of an interruption in drying? Humidity monitoring, a service-friendly design and the option to use a customer-supplied external UPS.
Maintenance What routine maintenance tasks and downtime should be expected? Low-maintenance design intended for long-term operation.
Calibration Does the entire cabinet need to be transported for calibration? Removable humidity meter that can be calibrated separately.
Repair Can individual components be replaced? Replaceable dry units and, depending on the model, timer components.
Long-Term Costs What costs may arise from servicing, inspections and potential interruptions? A comprehensive approach that also considers operational requirements after purchase.
The Key Question: What is the value of the materials stored in your dry cabinet — and what would be the consequences of an unexpected interruption to their required storage conditions?
POWER-OFF HUMIDITY PERFORMANCE

What Happens to Humidity During a Power Outage?

A power outage does not mean that humidity inside a McDry dry cabinet will rise immediately. Even when the dehumidifying unit stops operating, the humidity inside the cabinet can remain low for a period of time.

The following measurements show how relative humidity changed after the power was switched off in two McDry cabinet models.

MEASURED EXAMPLE 01

DXU-1001A

Power OFF
DXU-1001A McDry dry cabinet: measured relative humidity after power off
MEASURED EXAMPLE 02

MCU-401

Power OFF
MCU-401 McDry dry cabinet: measured relative humidity after power off

Why Does the Humidity Fluctuate?

The graphs show some temporary increases and decreases in relative humidity. Because relative humidity is affected by temperature, changes in ambient temperature can cause these fluctuations.

Important Information

These test results are provided for reference only and do not guarantee humidity retention during a power outage. Actual performance may vary depending on the cabinet model, ambient conditions, loading, door opening and other operating factors.

ADDITIONAL PROTECTION

What If Continuous Humidity Control Is Essential?

For particularly sensitive materials or critical storage applications, additional protection may be required. A properly selected uninterruptible power supply (UPS) can keep the dehumidifying system operating temporarily during a power interruption.

Learn more about UPS backup protection below
OPTIONAL POWER OUTAGE PROTECTION

Additional Protection During Power Outages – With a UPS.

An external uninterruptible power supply (UPS) can provide temporary backup power to a McDry dry cabinet in the event of a mains power failure. The available backup time depends on the UPS and the connected electrical load.

Illustrative image of a McDry dry cabinet with an external UPS

Illustrative image: McDry with an external UPS

01 · Supply Voltage

The UPS must be compatible with the dry cabinet's required power supply, for example 230 V / 50 Hz.

02 · Output Waveform

A UPS with a pure sine wave output is recommended when selecting a suitable system.

03 · Power Capacity

The UPS output power rating must exceed the maximum power consumption of the connected dry cabinet.

04 · Backup Runtime

The required battery capacity depends on the desired backup duration and actual operating conditions.

Important Notice: The UPS must be purchased and installed separately by the customer. Seika Sangyo GmbH does not supply UPS systems. A UPS cannot prevent every possible technical malfunction and does not guarantee a specific humidity level. Compatibility and backup runtime must be evaluated individually.
CALIBRATION & QUALITY ASSURANCE

Calibration Without Transporting the Entire Cabinet.

The removable humidity meter is a practical advantage of McDry's service-friendly design. When calibration is required, the meter can be handled separately. There is no need to transport the entire dry cabinet for this purpose.

Removable McDry humidity meter

Removable Humidity Meter

01

Remove

The humidity meter is removed from the cabinet according to the prescribed procedure.

02

Have It Calibrated

The meter is sent separately for calibration. The scope and requirements are agreed upon in advance.

03

Reinstall

After calibration, the meter is reinstalled and its functionality is checked.

SIMPLER CALIBRATION WORKFLOW

Why Does a Removable Humidity Meter Matter?

Calibration is not only about measurement accuracy. Depending on the equipment design, it may also involve service appointments, engineer travel and on-site work. McDry's removable humidity meter offers a simpler approach to routine calibration.

ALTERNATIVE SERVICE APPROACH

On-site Calibration Service

For equipment requiring an on-site service visit, calibration may involve several additional arrangements.

Schedule
Visit
Engineer
Travels
On-site
Work
  • Engineer appointment and scheduling may be required
  • Travel and on-site service charges may apply
  • Access to the cabinet may need to be coordinated

More service coordination and potentially higher costs.

THE MCDRY ADVANTAGE

Removable Humidity Meter

With McDry, the humidity meter can be removed and calibrated separately, while the cabinet remains in place.

Remove
Meter
Separate
Calibration
Reinstall
Meter
  • No engineer visit required for routine meter calibration
  • No need to transport the entire cabinet
  • Simpler planning with potentially lower service-related costs

Less Service Coordination. Less Disruption.

Keep the Cabinet in Place. Send Only the Humidity Meter.

McDry's removable humidity meter helps simplify routine calibration without arranging an engineer visit to the customer's site for that purpose.

The comparison illustrates possible differences between service approaches. Actual calibration procedures, service costs and engineer requirements depend on the equipment, supplier and service agreement. Other technical repairs may still require on-site service. While the McDry humidity meter is removed, the corresponding humidity display is unavailable. Calibration intervals and required documentation depend on the user's specifications.

APPLICATIONS & INDUSTRIES

Dry Storage for Demanding Applications.

Different materials have different storage requirements. McDry offers a range of dry cabinet models that can be selected according to the required humidity level, storage capacity and operating conditions.

01

Electronics & SMT

Moisture-sensitive electronic components, printed circuit board assembly and the organisation of dry storage areas in electronics manufacturing.

02

Semiconductors & Precision Electronics

Controlled storage environments for suitable sensitive components and materials used in technical production and development facilities.

03

Battery Technology

Potential applications involving moisture-sensitive components and materials. Suitability must be evaluated based on the specific material and process requirements.

04

Medical Technology

Potential dry storage applications for suitable electronic components and technical materials. Product-specific quality and regulatory requirements must be assessed separately.

Which Solution Is Right for Your Application? The key factors are the materials to be stored, the required relative humidity, storage capacity and specific process requirements. Our team can help you select the most suitable McDry model.
PERSONAL CONSULTATION

Find the Right McDry Solution for Your Requirements.

Are you looking to select a new dry cabinet, improve your existing storage processes, or do you have questions about maintenance, calibration and spare parts? Seika Sangyo GmbH is here to help.

✓ Selection of the Right McDry Model
✓ Required Humidity Level and Storage Capacity
✓ Maintenance, Calibration and Spare Parts
✓ Optional Features and Technical Requirements
Request a Consultation →

To help us provide tailored advice, please include information about the materials to be stored, the required humidity level, storage capacity and installation location.